Model: | Patch Panel | Bnad: | Zion Communication |
---|---|---|---|
Cords: | ZCPP197 N5/6/7/8 |
More detail please visit:
https://www.zion-communication.com/Copper-System-Equipment.html
ZCPP197N5 | ||||||||||
Cat5e patch panel | ||||||||||
![]() |
||||||||||
Features | Order Information | |||||||||
∙ Meet ISO/IEC 11801,TIA/EIA568C. ∙ Fit for wires AWG22-26. ∙ IDC contacts: Maximum 200 reterminations. ∙ Min. life 750 insertions. ∙ Material: PC/ABS for cover, PC for module phosphor bronze for IDC. ∙ The internal PCB is directly screwed onto the iron panel. The whole product is strong and stable without any looseness. ∙ Dual IDC. |
Item No. | Description | ||||||||
ZCPP197-24N5-1U5E | Cat5e 19",1U,24 ports | |||||||||
ZCPP197-48N5-2U5E | Cat5e 19",1U,48 ports | |||||||||
ZCPP197N6 | ||||||||||
Cat.6 patch panel | ||||||||||
![]() |
||||||||||
Features | Order Information | |||||||||
∙ Meet ISO/IEC 11801,TIA/EIA568C. ∙ Fit for wires AWG22-26. ∙ IDC contacts: Maximum 200 reterminations. ∙ Min. life 750 insertions. ∙ Material: PC/ABS for cover, PC for module phosphor bronze for IDC. ∙ The internal PCB is directly screwed onto the iron panel. The whole product is strong and stable without any looseness. ∙ Dual IDC. |
Item No. | Description | ||||||||
ZCPP197-24N6-1U6 | Cat6 19",1U,24ports | |||||||||
ZCPP197-48N6-2U6 | Cat6 19",2U,48 ports | |||||||||
ZCPP197N7 | ||||||||||
Cat5e patch panel | ||||||||||
![]() |
||||||||||
Features | Order Information | |||||||||
∙ Meet ISO/IEC 11801,TIA/EIA568C. ∙ Fit for wires AWG22-26. ∙ IDC contacts: Maximum 200 reterminations. ∙ Min. life 750 insertions. ∙ Material: PC/ABS for cover, PC for module phosphor bronze for IDC. ∙ The internal PCB is directly screwed onto the iron panel. The whole product is strong and stable without any looseness. ∙ Dual IDC. ∙ Slide label field. |
Item No. | Description | ||||||||
ZCPP197-24N7-1U5E | Cat5e 19",1U,24 ports | |||||||||
ZCPP197-48N7-2U5E | Cat5e 19",1U,48 ports | |||||||||
ZCPP197N8 | ||||||||||
Cat.6 patch panel | ||||||||||
![]() |
||||||||||
Features | Order Information | |||||||||
∙ Meet ISO/IEC 11801,TIA/EIA568C. ∙ Fit for wires AWG22-26. ∙ IDC contacts: Maximum 200 reterminations. ∙ Min. life 750 insertions. ∙ Material: PC/ABS for cover, PC for module phosphor bronze for IDC. ∙ The internal PCB is directly screwed onto the iron panel. The whole product is strong and stable without any looseness. ∙ Dual IDC. ∙ Slide label field. |
Item No. | Description | ||||||||
ZCPP197-24N8-1U6 | Cat6 19",1U,24ports | |||||||||
ZCPP197-48N8-2U6 | Cat6 19",2U,48 ports | |||||||||